Products


GCS type low-voltage draw-out switchgear


Classification:

Low-Voltage Switchgear


GCS low voltage withdrawable switchgear is suitable for power plant, petroleum, chemical, metallurgy, textile, high-rise building and other low voltage distribution system.
● Compact structure to accommodate more functional units in a smaller space.
● The main frame of the device is made of 8MF steel, and there are installation modulus holes E=20㎜ on the main frame. The parts have strong versatility and flexible assembly.
● Using standard module design, there are five size series of standard units, users can choose to assemble according to needs.

Product Description


Product Overview

 

GCS low voltage withdrawable switchgear is suitable for power plant, petroleum, chemical, metallurgy, textile, high-rise building and other low voltage distribution system.

● Compact structure to accommodate more functional units in a smaller space.

● The main frame of the device is made of 8MF steel, and there are installation modulus holes E=20㎜ on the main frame. The parts have strong versatility and flexible assembly.

● Using standard module design, there are five size series of standard units, users can choose to assemble according to needs.

● The separation between functional units and compartments is clear, reliable, and does not affect the work of other units due to the failure of a certain unit, so that the fault is localized in a small range.

● The drawer unit is equipped with a mechanical interlocking device, and the drawer panel has obvious signs such as parting, closing, testing, and drawing out

 


 

Environmental conditions

 

1

Ambient temperature:

Not higher than +40℃, not lower than -15℃. And the average temperature within 24h shall not exceed +35℃.

2

Altitude:

No more than 2000m above sea level.

3

Relative humidity:

The daily average does not exceed 95% and the monthly average does not exceed 90%.

4

Contamination levels:

Level III.

5

 

A place free from fire, explosion danger, serious filth, chemical corrosion, and violent vibration.

6

 

Place free from violent vibration and jolting.

 


 

Performance parameters

 

Serial number

Name

Units

Numerical value

1

Rated operating voltage

V

380/690

2

Rated insulation voltage

V

660/1000

3

Rated frequency

Hz

50/60

4

Rated current of the main bus

A

≤6300

5

Rated short-time withstand current of main bus (1S)

kA

≤100

6

Rated peak withstand current

kA

≤220

7

Rated current of the distribution bus

A

≤1000

8

Rated short-time withstand current of distribution bus (1S)

kA

≤65

9

Distribution bus peak withstand current

kA

≤143

10

1min auxiliary circuit power frequency withstand voltage

kV

2

11

Rated pulse withstand voltage

kV

8

12

Grade of enclosure protection

IP

To IP54

13

Electrical clearance

mm

≥10

14

Creepage distance

mm

≥12.5

Previous

GGD type AC low-voltage switchgear

Packaging Shipping

Shipment 4

Shipment 3

Shipment 2

Shipment 1

Packaging 2

Packaging 1

Factory workshop

Bracket temporary storage area

Component unpacking area

Primary line

Copper bar prefabrication area

Application Field

New energy

New energy

New energy

Petrochemical industry

Petrochemical industry

Petrochemical industry

Coal

Coal

Coal

Steel works

Steel works

Steel works

Electricity (gas)

Electricity (gas)

Electricity (gas)

Quality Certificate

XM-Meter Box-CQC
XL21-600A-CQC
WZBLJ capacitor cabinet-CQC
SIVACON-8PT-1600~3150A-CQC
PZ30 lighting box CQC
MD_MAX-1600~4000A-CQC

FAQ

LANKONG

How long is the after-sales response time?


LANKONG

We have a 24-hour after-sales service hotline, after receiving customer's after-sales request, we will make an initial response within 2-4 hours. For emergencies, we will arrange technicians to rush to the scene in the shortest possible time, the specific time depends on the geographical location of the customer, but we will do our best to ensure that we arrive at the scene within 24 hours (domestic) to solve the problem.

LANKONG

What does the after-sales service of your complete set of switchgear include?


LANKONG

Our after-sales service is very comprehensive. The first is the free repair and replacement service during the warranty period. If the equipment has quality problems during the warranty period, we will respond in time and repair or replace the faulty parts free of charge. Secondly, we provide lifelong technical support, whenever customers encounter technical problems related to equipment, you can contact our technicians, we will provide solutions. In addition, we can also provide regular equipment maintenance services according to customer needs, including equipment cleaning, inspection, fastening screws, electrical performance testing and other content, in order to extend the service life of the equipment.

LANKONG

How to debug the equipment after installation?


LANKONG

After the equipment is installed, debugging is a key step to ensure its normal operation. We will arrange professional technicians to carry out debugging, or provide customers with detailed debugging guidelines. The debugging mainly includes the measurement and setting of electrical parameters, such as the detection and calibration of voltage, current, frequency and other parameters; Testing of various protection functions, such as trigger test of overcurrent protection, short-circuit protection, grounding protection and other functions; And the communication function test of the equipment (if the equipment has a communication interface) to ensure that it can communicate with the host computer or other monitoring systems normally.

LANKONG

Is your switchgear set complicated to install? Do you need professional personnel?


LANKONG

The installation of our complete sets of switchgear has certain technical requirements, and it is best to be operated by professional electrical installers. However, we will provide a detailed installation manual and operating guide, which includes the installation steps of the equipment, electrical connection diagram, safety precautions and so on. During the installation process, if you encounter any problems, our technical support team can also provide remote guidance or on-site installation services.

LANKONG

How is the adaptability of the switchgear cabinet in various application conditions?


LANKONG

The creepage distance of the switchgear insulation support is greater than 240mm, and it has passed the special "condensation test" performance test, proving that it has good application under the cold conditions in northern Europe and the hot environment in southern China, showing good adaptability to various application conditions.

LANKONG

Compared with other brands, what are the advantages of your switchgear sets?


LANKONG

Our products have several significant advantages. First, in terms of technological innovation, we invest a lot of resources in research and development and have our own patented technologies, such as in intelligent control and protection systems, which enable more accurate fault diagnosis and rapid protection of our equipment. Second, in terms of quality, we have established a sound quality management system, from raw material procurement to finished products, every link is strictly controlled to ensure that product quality is higher than the industry standard. Third, customized services, we can according to the special needs of customers, such as special electrical parameters, cabinet size and functional requirements, to provide personalized complete sets of switchgear solutions.

LANKONG

How do you guarantee the reliability of your products?


LANKONG

Our switchgear sets are designed with high reliability in mind. First of all, the selected key components are from well-known brands such as Schneider, ABB, Siemens, etc., and have gone through strict quality testing to ensure stable performance. Secondly, our equipment in the production process, follow the strict production process and quality control standards, each process is inspected by professional personnel. In addition, we also carried out a variety of reliability tests on the equipment, such as voltage test, short circuit withstand current test, etc., to ensure that the equipment can work stably and reliably in long-term operation.

LANKONG

What is the rated voltage and current range of your products?


LANKONG

For low-voltage switchgear sets, the rated voltage is generally between 380V-690V, and the rated current can range from hundreds of amps to thousands of amps, depending on the model and design specifications of the product. The rated voltage of high-voltage switchgear sets is common 10kV, 35kV, etc. The rated current ranges from hundreds of amps to thousands of amps according to different application scenarios and equipment requirements, such as the rated current of 12kV switchgear may be between 630A-3150A.

LANKONG

What are the main components of a switchgear set?


LANKONG

complete set of switchgear includes circuit breaker, isolation switch, load switch, current transformer, voltage transformer, fuse, bus, relay protection device, measurement and control device, operating mechanism and various cabinets, etc. These components work together to control, protect and distribute electrical energy. For example, a circuit breaker is used to cut and switch on a circuit, a current transformer is used to measure the amount of current in a circuit, and a relay protection device can act quickly in the event of a fault to protect equipment and lines.

LANKONG

What are the main types of switchgear sets in your company?


LANKONG

Our company produces many types of complete switchgear sets, including low voltage switchgear sets (LMNS low voltage cabinet, SIVACON 8PT low voltage cabinet, Blokset low voltage cabinet, MD_max low voltage cabinet, iLMNS intelligent low voltage cabinet, GCS, GGD), high voltage switchgear sets (: KYN61-40.5 type medium voltage distribution switchgear, KYN28-12 type medium voltage distribution switchgear, KYN28-24 type medium voltage distribution switchgear, LJ-XGN-12 type solid insulated AC metal closed switchgear), busbar trough, pre-installed substation, power supply equipment (GZDC type DC screen, EPS fire emergency power supply), etc. These devices can be selected according to different voltage levels, uses and use environments.

Contact Us

%{tishi_zhanwei}%